Get NFPA CFI-I Practice Test For Quick Preparation [2025]
The scoring system of our CFI-I exam torrent absolutely has no problem because it is intelligent and powerful. First of all, our researchers have made lots of efforts to develop the scoring system. So the scoring system of the CFI-I test answers can stand the test of practicability. Once you have submitted your practice. The scoring system will begin to count your marks of the CFI-I Exam guides quickly and correctly. At the same time, there is specific space below every question for you to make notes. So you can quickly record the important points or confusion of the CFI-I exam guides.
NFPA CFI-I Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Topic 4
Exam NFPA CFI-I Labs & CFI-I Trustworthy Source
In order to cater to different kinds of needs of customers, three versions for CFI-I learning materials are available. You can choose one you prefer according to your own needs. CFI-I PDF version is printable and you can study anywhere and anyplace. CFI-I Soft test engine supports MS operating system and have two modes for practice. In addition, CFI-I Soft test engine can simulate the real exam environment, and your confidence for the exam can be strengthened through this version. CFI-I Online test engine is convenient and easy to study, it supports all web browsers, and it has testing history and performance review, so that you can have a general review before next training.
NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q29-Q34):
NEW QUESTION # 29
The authorization to issue permits is granted by the
Answer: A
Explanation:
The authority having jurisdiction (AHJ) is the entity responsible for enforcing codes, standards, and regulations, including the authorization to issue permits.
The AHJ is defined as the organization, office, or individual responsible for approving plans, issuing permits, and ensuring compliance.
While state legislatures (A) may create laws, the actual enforcement and issuance of permits are delegated to the AHJ.
Fire Inspection Handbooks (C) and NFPA 101 (D) are reference tools but do not directly grant authority.
Reference:
NFPA 1, Fire Code, Section 3.2.2: Defines the AHJ's role and responsibilities.
NFPA 101: Acknowledges the AHJ as the enforcement body.
NEW QUESTION # 30
Fire extinguishers having a gross weight not exceeding 40 lb (18.14 kg) shall be installed to which of the following criteria?
Answer: B
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Installation Height Requirements for Fire Extinguishers:
According to NFPA 10 (Standard for Portable Fire Extinguishers), Section 6.1.3.8, fire extinguishers with a gross weight not exceeding 40 lb (18.14 kg) must be installed so that the top of the extinguisher is not more than 5 ft. (1.53 m) above the floor.
Why This Height is Important:
A maximum height of 5 feet ensures accessibility to fire extinguishers for most people during emergencies.
Other Options Explained:
Option A (5 ft. 6 in): Exceeds the NFPA 10 limit and is too high for practical use.
Option C and D (Bottom of the extinguisher): NFPA 10 specifies the height based on the top of the extinguisher, not the bottom.
Summary:
Fire extinguishers with a weight not exceeding 40 lb must have their top installed no more than 5 feet (1.53 m) above the floor.
NEW QUESTION # 31
A vehicle fuel dispenser for LP-Gas, installed under a weather shelter or canopy, shall not be enclosed by more than what percentage of its perimeter?
Answer: C
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
LP-Gas Fuel Dispenser Requirements:
According to NFPA 58 (Liquefied Petroleum Gas Code), Section 6.24.3.14, a vehicle fuel dispenser for LP-Gas under a weather shelter or canopy shall not be enclosed by more than 50 percent of its perimeter.
Reason for Limiting Enclosure:
Proper ventilation is required to prevent the accumulation of LP-Gas vapors, which are heavier than air and can pose an explosion hazard if confined.
Other Options Explained:
Option A (10 percent) and Option B (25 percent): Too restrictive; adequate ventilation can be achieved with up to 50% enclosure.
Option D (75 percent): Exceeds the allowable limit and may trap vapors, creating a hazard.
Summary:
LP-Gas vehicle fuel dispensers under a shelter or canopy shall not be enclosed by more than 50 percent of their perimeter.
NEW QUESTION # 32
While conducting an inspection, a fire inspector observes a hazardous condition that presents an imminent danger to the occupants of the building being inspected. What action should the inspector take?
Answer: D
Explanation:
If a hazardous condition presents an imminent danger, the fire inspector must take immediate action to protect the occupants. The appropriate response is to order the immediate evacuation (D) of the building until the hazard is resolved.
Imminent danger requires decisive action to prevent harm.
Evacuation (D) ensures occupant safety while corrective actions are implemented.
Leaving the building (A): Neglects the inspector's duty to safeguard lives.
Remaining on-site (B, C): Does not adequately address the immediate danger.
Reference:
NFPA 1, Section 3.2.2: Authority of inspectors in cases of imminent danger.
NEW QUESTION # 33
What is a system that discharges water from open sprinklers activated by a detection system called?
Answer: B
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Deluge Systems:
A deluge system is a fire sprinkler system in which all sprinklers are open, and water is discharged simultaneously when activated by a separate detection system (e.g., heat or smoke detection).
Key Characteristics of a Deluge System:
Sprinkler heads are open, with no heat-sensitive element.
The piping is not pressurized with water until the detection system activates the deluge valve.
Commonly used in high-hazard areas like aircraft hangars or flammable liquid storage facilities.
Other Options Explained:
Option A (Wet-pipe system): Pipes are filled with water, and only heat-activated sprinklers discharge water.
Option B (Dry-pipe system): Pipes contain air or nitrogen; water enters after a sprinkler activates.
Option C (Preaction system): Combines elements of dry-pipe and detection systems but does not discharge from all open sprinklers.
Summary:
A deluge system discharges water from open sprinklers activated by a detection system.
NEW QUESTION # 34
......
We value every customer who purchases our CFI-I test material and we hope to continue our cooperation with you. Our CFI-I test questions are constantly being updated and improved so that you can get the information you need and get a better experience. The services provided by our CFI-I test questions are quite specific and comprehensive. First of all, our test material comes from many experts. The gold content of the materials is very high, and the updating speed is fast. By our CFI-I Exam Prep, you can find the most suitable information according to your own learning needs at any time, and make adjustments and perfect them at any time.
Exam CFI-I Labs: https://www.surepassexams.com/CFI-I-exam-bootcamp.html